{"id":5427,"date":"2026-10-26T10:45:26","date_gmt":"2026-10-26T02:45:26","guid":{"rendered":"https:\/\/xinya-ee.com\/blog\/evse-technician-training-certification\/"},"modified":"2026-10-26T11:05:19","modified_gmt":"2026-10-26T03:05:19","slug":"evse-technician-training-certification","status":"publish","type":"post","link":"https:\/\/xinya-ee.com\/fr\/blog\/evse-technician-training-certification\/","title":{"rendered":"Quels formations et certificats ont-ils besoin les techniciens de bornes de recharge ?"},"content":{"rendered":"<article>\n<div class=\"xydf-blog-20261026\">\n<style>.xydf-blog-20261026{max-width:100%;min-width:0;overflow-wrap:break-word}.xydf-blog-20261026 figure{margin:28px 0}.xydf-blog-20261026 figure img{display:block;width:100%;max-width:100%;height:auto}.xydf-blog-20261026 figcaption{font-size:14px;line-height:1.6;margin-top:8px;color:#555}.xydf-blog-20261026 th,.xydf-blog-20261026 td{padding:12px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:break-word;border:1px solid #d8dde8}.xydf-blog-20261026 th{background:#f4f5f9}.xydf-blog-20261026 ul{display:block;padding-left:1.5em}.xydf-blog-20261026 li{display:list-item;line-height:1.7;margin-bottom:10px}<\/style>\n<p><strong>Formation des techniciens EVSE<\/strong> Ce cours doit correspondre au travail que le technicien effectuera r\u00e9ellement : installation d\u2019un circuit \u00e9lectrique, mise en service d\u2019un chargeur de v\u00e9hicule \u00e9lectrique, diagnostic d\u2019une panne r\u00e9seau ou remplacement d\u2019un composant \u00e9lectrique. Un simple certificat de cours ne permet pas d\u2019obtenir l\u2019autorisation ou la comp\u00e9tence n\u00e9cessaires pour effectuer ces quatre t\u00e2ches. Les op\u00e9rateurs commerciaux doivent poss\u00e9der les qualifications \u00e9lectriques locales appropri\u00e9es, une formation de s\u00e9curit\u00e9 sp\u00e9cifique \u00e0 chaque t\u00e2che et une instruction pratique sur le mat\u00e9riel \u00e0 r\u00e9parer.<\/p>\n<p>Commencez par s\u00e9parer trois questions : la personne est-elle l\u00e9galement autoris\u00e9e \u00e0 effectuer le travail, est-elle capable de g\u00e9rer les risques \u00e9lectriques associ\u00e9s, et peut-elle d\u00e9montrer la proc\u00e9dure sur le chargeur pertinent ? Les r\u00e9ponses d\u00e9terminent qui peut installer, inspecter, configurer et r\u00e9parer l\u2019installation.<\/p>\n<h2>Quelles qualifications sont n\u00e9cessaires avant que la formation sur les chargeurs de v\u00e9hicules \u00e9lectriques ne commence ?<\/h2>\n<p>Local licensing rules come first. An electrician&#8217;s license, contractor registration or other authorization may be required for fixed wiring and electrical installation. Requirements differ by jurisdiction, so an EV charging course should not be treated as a substitute for the qualifications that the project authority requires.<\/p>\n<p><strong>Certification d'installateur de chargeurs \u00e9lectriques<\/strong> Il fournit des preuves suppl\u00e9mentaires de l\u2019apprentissage sp\u00e9cifique au chargeur. Sa valeur d\u00e9pend du programme d\u2019\u00e9tudes, de l\u2019\u00e9valuation et de la reconnaissance par le client, du programme de financement ou de l\u2019autorit\u00e9 locale. Les acheteurs doivent v\u00e9rifier si la certification couvre l\u2019installation de chargeurs CA, le travail sur les chargeurs DC rapides, l\u2019inspection, la mise en service ou uniquement la th\u00e9orie de base.<\/p>\n<p>Par exemple, les exigences am\u00e9ricaines en mati\u00e8re de <a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/23\/680.106\" target=\"_blank\" rel=\"noopener\">23 CFR 680.106(j)<\/a> d\u00e9finir les qualifications des personnels n\u00e9cessaires \u00e0 l\u2019exploitation des infrastructures de recharge couvertes par cette r\u00e9glementation. Ces qualifications comprennent un parcours d\u2019\u00e9tudes pour les v\u00e9hicules \u00e9lectriques et un parcours d\u2019apprentissage agr\u00e9\u00e9 qualifiant. Elles ne devraient pas \u00eatre pr\u00e9sent\u00e9es comme une r\u00e8gle d\u2019agr\u00e9ment universelle applicable \u00e0 tous les projets de recharge de v\u00e9hicules \u00e9lectriques dans le monde. Lisez les conditions de financement applicables en parall\u00e8le avec les exigences d\u2019agr\u00e9ment.<\/p>\n<h2>Quelles comp\u00e9tences en s\u00e9curit\u00e9 \u00e9lectrique doit un technicien de chargeur \u00e9lectrique acqu\u00e9rir ?<\/h2>\n<p>Efficace <strong>Formation sur la s\u00e9curit\u00e9 des chargeurs \u00e9lectriques<\/strong> Il couvre les risques de choc, l\u2019\u00e9nergie stock\u00e9e, l\u2019isolement s\u00fbr, le mat\u00e9riel de protection appropri\u00e9 et le moment o\u00f9 il faut interrompre le travail. Les chargeurs rapides DC peuvent contenir des composants de stockage d\u2019\u00e9nergie et plus d\u2019une source d\u2019alimentation ou de commande pertinente. Un bouton d\u2019arr\u00eat d\u2019urgence, un \u00e9cran noir ou une commande de fermeture \u00e0 distance ne prouvent pas en soi que le mat\u00e9riel est \u00e9lectriquement isol\u00e9.<\/p>\n<p>\u00c9tats-Unis <a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.332\" target=\"_blank\" rel=\"noopener\">29 CFR 1910.332<\/a> ties electrical safety training to the employee&#8217;s job assignments and risk. It identifies additional knowledge needed by qualified persons, including recognizing exposed live parts and understanding relevant voltages and clearances. This is a useful distinction between basic site awareness and qualification for electrical tasks.<\/p>\n<p>Le cours pratique doit \u00e9galement traiter de la proc\u00e9dure d'isolation sp\u00e9cifique \u00e0 chaque \u00e9quipement, de la v\u00e9rification de l'arr\u00eat de la fourniture d'\u00e9nergie et des pr\u00e9cautions \u00e0 prendre en cas de stockage d'\u00e9nergie. <a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.333\" target=\"_blank\" rel=\"noopener\">29 CFR 1910.333<\/a> Ces proc\u00e9dures s\u2019appliquent aux activit\u00e9s de maintenance \u00e9lectrique, y compris le d\u00e9senergagement, le verrouillage ou l\u2019\u00e9tiquetage, la v\u00e9rification et le red\u00e9marrage de l\u2019alimentation \u00e9lectrique. D\u2019autres r\u00e8gles relatives aux dangers li\u00e9s aux \u00e9nergies peuvent s\u2019appliquer \u00e0 cette t\u00e2che. Aucun de ces proc\u00e9dures ne doit \u00eatre improvis\u00e9 \u00e0 partir d\u2019une liste de contr\u00f4le g\u00e9n\u00e9rique trouv\u00e9e sur un blog.<\/p>\n<p>Arc-flash instruction should explain the site&#8217;s assessment, work controls and task-specific protective measures. A short awareness session does not authorize energized work. The employer must determine qualification and authorization for the actual assignment, using the applicable regulations and safety program.<\/p>\n<h2>Quelles comp\u00e9tences pratiques doit d\u00e9montrer un technicien ?<\/h2>\n<p>L\u2019apprentissage en classe est n\u00e9cessaire, mais un op\u00e9rateur commercial doit \u00e9galement observer les performances. Une \u00e9valuation pratique devrait utiliser le mod\u00e8le pr\u00e9vu ou un dispositif de formation supervis\u00e9 appropri\u00e9, avec un observateur qui enregistre ce que le technicien peut accomplir de mani\u00e8re ind\u00e9pendante et ce qui n\u00e9cessite encore une supervision.<\/p>\n<p>For installation work, the technician should interpret the approved drawings, recognize equipment ratings, follow the manufacturer&#8217;s connection and tightening instructions, and understand the required local inspection and testing. Exterior checks should include the enclosure, connector housing, cable condition, mounting and access around the equipment.<\/p>\n<figure data-image-role=\"training-cable\"><img alt=\"Exterior visual inspection of the stored cable on a genuine XYDF wall-mounted EV charger; annotated with Cable condition, Connector housing\" class=\"wp-image-5431\" decoding=\"async\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/xinya-ee.com\/wp-content\/uploads\/2026\/10\/20261026-training-cable-annotated-v1.webp\" width=\"1536\"\/><figcaption>L\u2019inspection ext\u00e9rieure couvre l\u2019\u00e9tat des c\u00e2bles et des connecteurs visibles. Elle ne certifie pas que les circuits internes soient s\u00fbrs \u00e0 toucher.<\/figcaption><\/figure>\n<p>Pour la mise en service, l\u2019\u00e9valuation devrait couvrir la s\u00e9quence d\u2019amor\u00e7age document\u00e9e, les modifications de configuration autoris\u00e9es, la v\u00e9rification des sessions de charge et l\u2019enregistrement des r\u00e9sultats des essais. Dans le cas o\u00f9 des fonctions de paiement, d\u2019autorisation ou de gestion de la charge sont incluses, le technicien doit v\u00e9rifier ces fonctionnalit\u00e9s dans le cadre du contrat plut\u00f4t que de d\u00e9clarer la station pr\u00eate apr\u00e8s avoir v\u00e9rifi\u00e9 uniquement que son \u00e9cran s\u2019allume.<\/p>\n<p><strong>Formation des techniciens charg\u00e9s de la recharge des v\u00e9hicules \u00e9lectriques<\/strong> Il devrait inclure une remise en main propre r\u00e9aliste. L\u2019\u00e9valuateur devrait demander au technicien d\u2019expliquer une panne, de fournir des preuves \u00e0 l\u2019appui, de pr\u00e9ciser si une intervention \u00e9lectrique est autoris\u00e9e et de noter les prochaines actions \u00e0 mener. Cette proc\u00e9dure r\u00e9v\u00e8le des lacunes que le test \u00e0 choix multiples pourrait manquer de d\u00e9tecter.<\/p>\n<div style=\"width:100%;max-width:100%;overflow-x:auto;margin:24px 0\">\n<table style=\"width:100%;border-collapse:collapse;table-layout:auto\">\n<thead>\n<tr>\n<th scope=\"col\">Travail assign\u00e9<\/th>\n<th scope=\"col\">Capacit\u00e9 \u00e0 d\u00e9montrer<\/th>\n<th scope=\"col\">Evidences \u00e0 conserver<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Inspection ext\u00e9rieure<\/td>\n<td>Reconna\u00eetre les dommages visibles et les signaler sans ouvrir l'appareil<\/td>\n<td>Rapports d\u2019inspection et d\u00e9cision d\u2019escalade<\/td>\n<\/tr>\n<tr>\n<td>Installation \u00e9lectrique<\/td>\n<td>Interpr\u00e9ter les dessins et effectuer l\u2019installation et la v\u00e9rification autoris\u00e9es<\/td>\n<td>Contr\u00f4les de licence, registres d'inspection et d'essai applicables<\/td>\n<\/tr>\n<tr>\n<td>Entretien<\/td>\n<td>Suivez la proc\u00e9dure d'amor\u00e7age approuv\u00e9e et v\u00e9rifiez les fonctions sp\u00e9cifi\u00e9es<\/td>\n<td>Rapport de mise en service sp\u00e9cifique au mod\u00e8le<\/td>\n<\/tr>\n<tr>\n<td>Diagnostic \u00e0 distance<\/td>\n<td>Revoir la connectivit\u00e9, les journaux de session et les param\u00e8tres autoris\u00e9s<\/td>\n<td>Evidences de faute, enregistrement des changements et r\u00e9sultats<\/td>\n<\/tr>\n<tr>\n<td>Remplacement des composants<\/td>\n<td>Effectuez une r\u00e9paration autoris\u00e9e selon la proc\u00e9dure de service correspondante.<\/td>\n<td>Validation des comp\u00e9tences, tra\u00e7abilit\u00e9 des pi\u00e8ces et v\u00e9rifications post-r\u00e9paration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Qu\u2019est-ce qui doit \u00eatre v\u00e9rifi\u00e9 avant la mise en service et la maintenance ?<\/h2>\n<p>Un technicien qualifi\u00e9 en installation \u00e9lectrique g\u00e9n\u00e9rale peut encore avoir besoin d\u2019instructions sp\u00e9cifiques au mod\u00e8le pour effectuer un entretien sur un chargeur rapide DC. L\u2019acc\u00e8s au service, les pr\u00e9cautions de d\u00e9charge, les outils de diagnostic, les pi\u00e8ces de rechange et les proc\u00e9dures de mise \u00e0 jour du firmware peuvent diff\u00e9rer selon les familles de produits. Le programme de formation doit identifier les mod\u00e8les et les t\u00e2ches concern\u00e9s.<\/p>\n<p>Utilisez la version correcte du manuel et confirmez qui peut autoriser les travaux. Distinguez l\u2019inspection externe de l\u2019ouverture de l\u2019enceinte, et isolez le red\u00e9marrage \u00e0 distance autoris\u00e9 des tentatives r\u00e9p\u00e9t\u00e9es de red\u00e9marrer l\u2019\u00e9quipement avec un signal d\u2019alarme \u00e9lectrique non r\u00e9solu. Les conditions de garantie et l\u2019autorisation de service doivent \u00eatre \u00e9tablies avant le d\u00e9but d\u2019une r\u00e9paration.<\/p>\n<figure data-image-role=\"training-access\"><img alt=\"Closed XYDF charger enclosure and unobstructed service approach during an exterior training walk-through; annotated with Closed enclosure, Clear service approach\" class=\"wp-image-5433\" decoding=\"async\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/xinya-ee.com\/wp-content\/uploads\/2026\/10\/20261026-training-access-annotated-v1.webp\" width=\"1536\"\/><figcaption>Un abri ferm\u00e9 et une approche de service claire favorisent un acc\u00e8s ext\u00e9rieur. L\u2019isolation \u00e9lectrique n\u00e9cessite une proc\u00e9dure et une v\u00e9rification sp\u00e9cifiques.<\/figcaption><\/figure>\n<p>Network configuration also needs controlled access. Technicians should understand the site&#8217;s connectivity method, charger identity, authorized backend endpoint and the OCPP version and features actually supported. They should be able to distinguish a communications failure from a charging or electrical fault, preserve relevant logs and escalate issues outside their role. Protocol familiarity alone does not qualify someone to repair a power stage.<\/p>\n<p>Routine work should connect to the operator&#8217;s <a href=\"https:\/\/xinya-ee.com\/fr\/blog\/guide-de-maintenance-des-stations-de-recharge-ev\/\">contr\u00f4les de maintenance<\/a>, Ainsi, les constatations d\u2019inspection, l\u2019historique des d\u00e9fauts et les r\u00e9parations effectu\u00e9es restent \u00e0 la disposition du technicien suivant.<\/p>\n<h2>Comment les op\u00e9rateurs devraient-ils comparer la formation et tenir des registres de comp\u00e9tences ?<\/h2>\n<p>Comparez les cours aux t\u00e2ches \u00e9nonc\u00e9es dans le contrat de service. Demandez des informations sur les exigences d\u2019entr\u00e9e, les travaux pratiques supervis\u00e9s, les crit\u00e8res d\u2019\u00e9valuation, la couverture des modules et les limites de la qualification. Un cours qui couvre uniquement l\u2019installation ne peut gu\u00e8re pr\u00e9parer la configuration ou le remplacement des composants de la puissance \u00e9lectrique.<\/p>\n<div style=\"width:100%;max-width:100%;overflow-x:auto;margin:24px 0\">\n<table style=\"width:100%;border-collapse:collapse;table-layout:auto\">\n<thead>\n<tr>\n<th scope=\"col\">Formation ou autorisation<\/th>\n<th scope=\"col\">Qu'est-ce que l'on doit v\u00e9rifier ?<\/th>\n<th scope=\"col\">Ce qui n\u2019est pas \u00e9tabli par lui-m\u00eame<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Licence ou enregistrement \u00e9lectrique<\/td>\n<td>Jurisdiction, validit\u00e9 et activit\u00e9s autoris\u00e9es<\/td>\n<td>Connaissances sur tous les mod\u00e8les de chargeurs de v\u00e9hicules \u00e9lectriques<\/td>\n<\/tr>\n<tr>\n<td>Formation sur l\u2019installation d\u2019un EVSE<\/td>\n<td>Programme d\u2019installation pertinent et \u00e9valuation pratique<\/td>\n<td>Permis pour toutes les r\u00e9parations internes<\/td>\n<\/tr>\n<tr>\n<td>Formation en s\u00e9curit\u00e9 \u00e9lectrique<\/td>\n<td>D\u00e9finition des dangers assign\u00e9s et des pratiques de travail<\/td>\n<td>Autorisation illimit\u00e9e pour des travaux \u00e9lectriques<\/td>\n<\/tr>\n<tr>\n<td>Formation de service aupr\u00e8s des fabricants<\/td>\n<td>Famille d'\u00e9quipements, proc\u00e9dures et t\u00e2ches \u00e9valu\u00e9es<\/td>\n<td>Substitution des qualifications locales requises<\/td>\n<\/tr>\n<tr>\n<td>Formation en r\u00e9seau et en back-end<\/td>\n<td>Fonctions support\u00e9es et acc\u00e8s contr\u00f4l\u00e9<\/td>\n<td>Qualification en maintenance \u00e9lectrique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Tenir un dossier de comp\u00e9tences pour chaque personne : d\u00e9tails concernant la licence ou la qualification, les versions des cours et des manuels pertinents, les \u00e9valuations pratiques, les t\u00e2ches autoris\u00e9es, le superviseur et les exigences de renouvellement. Le terme \u00ab certification EVSE \u00bb est souvent utilis\u00e9 de mani\u00e8re g\u00e9n\u00e9rale, il faut donc indiquer si un document certifie le technicien, un cours ou le mat\u00e9riel lui-m\u00eame.<\/p>\n<p>There is no single worldwide renewal interval. Follow the credential issuer&#8217;s rules and applicable safety requirements, and reassess competence when equipment, procedures or assignments change. A long gap in practice, an incident or an observed procedural error can also justify refresher training before the person resumes that task.<\/p>\n<p>Lors de la discussion sur XYDF <a href=\"https:\/\/xinya-ee.com\/fr\/ac-charger\/\">Chargeurs pour VE AC<\/a> ou <a href=\"https:\/\/xinya-ee.com\/fr\/chargeur-rapide-cc\/\">Chargeurs rapides CC<\/a>, Les exigences de qualification doivent \u00eatre conformes aux travaux r\u00e9els d\u2019installation et de maintenance, et non \u00e0 la simple mention d\u2019un cours.<\/p>\n<h2>Questions fr\u00e9quemment pos\u00e9es concernant la formation des techniciens EVSE<\/h2>\n<h3>Quels sont les comp\u00e9tences requises d\u2019un technicien de chargeur \u00e9lectrique ?<\/h3>\n<p>Le technicien doit suivre une formation \u00e9lectrique et de s\u00e9curit\u00e9 adapt\u00e9e au travail \u00e0 effectuer, ainsi que des cours pratiques sur le chargeur EV concern\u00e9 et ses fonctions r\u00e9seau. La combinaison requise d\u00e9pend de la licence locale, des exigences du projet et des proc\u00e9dures du fabricant.<\/p>\n<h3>Quelles certifications sont utiles pour l\u2019installation de chargeurs pour v\u00e9hicules \u00e9lectriques ?<\/h3>\n<p>Une qualification \u00e9lectrique locale valide constitue le point de d\u00e9part requis. Une certification reconnue sp\u00e9cifique aux chargeurs, telle qu\u2019un dipl\u00f4me d\u2019\u00e9tudes sup\u00e9rieures en \u00e9lectricit\u00e9 (EVITP) applicable ou un parcours d\u2019apprentissage qualifiant pour les projets couverts par les r\u00e8gles de financement am\u00e9ricaines, peut apporter des preuves pertinentes. Confirmez l\u2019acceptation aupr\u00e8s de l\u2019autorit\u00e9 du projet.<\/p>\n<h3>Le cours d\u2019installation d\u2019un syst\u00e8me de recharge \u00e9lectrique couvre-t-il la s\u00e9curit\u00e9 \u00e9lectrique et les proc\u00e9dures de verrouillage ?<\/h3>\n<p>It should cover the hazards and isolation procedures relevant to the course&#8217;s work scope. Check for practical assessment of safe work preparation and verification, rather than assuming a generic certificate includes those skills.<\/p>\n<h3>Quelles comp\u00e9tences pratiques devrait poss\u00e9der un technicien charg\u00e9 de la charge des v\u00e9hicules commerciaux ?<\/h3>\n<p>Le technicien doit d\u00e9montrer les t\u00e2ches d\u2019installation, d\u2019inspection, de mise en service ou de diagnostic qui lui sont assign\u00e9es, tout en reconnaissant les situations o\u00f9 il faut s\u2019arr\u00eater et faire appel \u00e0 des comp\u00e9tences plus sp\u00e9cialis\u00e9es. L\u2019\u00e9valuation doit \u00e9galement couvrir des enregistrements pr\u00e9cis et un retour au service contr\u00f4l\u00e9.<\/p>\n<h3>Qui peut installer et entretenir les chargeurs rapides DC ?<\/h3>\n<p>Le personnel doit poss\u00e9der les qualifications, la comp\u00e9tence pour effectuer les t\u00e2ches et l\u2019autorisation requises par la juridiction, l\u2019employeur et le fournisseur d\u2019\u00e9quipements. L\u2019exp\u00e9rience en mati\u00e8re d\u2019installation ne suffit pas \u00e0 \u00e9tablir la comp\u00e9tence pour effectuer des r\u00e9parations internes des chargeurs rapides DC.<\/p>\n<h3>Combien de fois les techniciens charg\u00e9s de la recharge des v\u00e9hicules \u00e9lectriques doivent-ils renouveler leur formation ou leur certification ?<\/h3>\n<p>Suivez les exigences applicables en mati\u00e8re de qualifications et de r\u00e9glementation. R\u00e9actualisez la formation et r\u00e9\u00e9valuez la comp\u00e9tence lorsque les \u00e9quipements, les dangers ou les proc\u00e9dures changent, ou lorsque les performances constat\u00e9es montrent un \u00e9cart. Il n\u2019existe pas de p\u00e9riode de renouvellement universelle pour tous les travaux relatifs aux bornes de recharge.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul style=\"padding-left:1.5em;line-height:1.7\">\n<li><a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.332\" target=\"_blank\" rel=\"noopener\">29 CFR 1910.332 : exigences en mati\u00e8re de formation en s\u00e9curit\u00e9 \u00e9lectrique<\/a>.<\/li>\n<li><a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.333\" target=\"_blank\" rel=\"noopener\">29 CFR 1910.333 : s\u00e9lection et utilisation des pratiques de travail \u00e9lectrique<\/a>.<\/li>\n<li><a href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/23\/680.106\" target=\"_blank\" rel=\"noopener\">23 CFR 680.106 : techniciens qualifi\u00e9s et infrastructure de recharge des v\u00e9hicules \u00e9lectriques couverts<\/a>.<\/li>\n<\/ul>\n<h2>Adapter l\u2019entra\u00eenement aux t\u00e2ches \u00e0 accomplir<\/h2>\n<p>A reliable training plan connects local qualifications, electrical safety, model-specific procedures and observed practical performance. It also states the limits of each person&#8217;s role. That combination gives an operator a stronger basis for assigning installation, commissioning and repair work than a certificate title alone.<\/p>\n<p style=\"margin-top:24px\">Pour un projet de recharge XYDF, <a href=\"https:\/\/xinya-ee.com\/fr\/contact-us\/\">d\u00e9battre des exigences d\u2019installation et de service<\/a> avec l'\u00e9quipe, y compris les \u00e9quipements pr\u00e9vus, les responsabilit\u00e9s du contractant local et la documentation n\u00e9cessaire \u00e0 la remise en main propre.<\/p>\n<\/div>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Apprenez quelles licences, comp\u00e9tences en s\u00e9curit\u00e9 \u00e9lectrique et formation pratique les techniciens des bornes de recharge pour v\u00e9hicules \u00e9lectriques doivent poss\u00e9der pour installer, mettre en service et entretenir les bornes de recharge commerciales.<\/p>","protected":false},"author":8,"featured_media":5432,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10,24],"tags":[],"product-features":[],"class_list":["post-5427","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-newsblog"],"_links":{"self":[{"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/posts\/5427","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/comments?post=5427"}],"version-history":[{"count":2,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/posts\/5427\/revisions"}],"predecessor-version":[{"id":5437,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/posts\/5427\/revisions\/5437"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/media\/5432"}],"wp:attachment":[{"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/media?parent=5427"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/categories?post=5427"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/tags?post=5427"},{"taxonomy":"xinya_product_feature","embeddable":true,"href":"https:\/\/xinya-ee.com\/fr\/wp-json\/wp\/v2\/product-features?post=5427"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}