1. Multifold charging protection such as input over/under voltage, connection abnormality, emergency stop
2. Protect against lightning, leakage, short circuit, over current, over temperature, reverse battery connection, etc
3. Modular design, flexible configuration and easy maintenance
4. High degree of protection and wide voltage output
5. Support swiping card/scan QR code to pay
6. Support CCS2, CCS1, GB/T standard fast charging
Model | XY DC-E180-60KW | XY DC-E180-80KW | ||
Input Parameters | Power Connection | 3P+N+PE | ||
Voltage & Frequency | 400VAC±10%; 45~65Hz | |||
Total Harmonic Wave Factor | THD<5% | |||
Power Factor | ≥0.99 | |||
Output Parameters | Voltage | 200-1000Vdc | ||
Max. Current | 100A*2 | 133A*2 | ||
Max. Power | 120 kW | 180 kW | ||
Number of Output Plugs | 2 | |||
Steady Current Precision | ±0.5% | |||
Output Current Precision | ≤±1% (≥30A) ≤0.3A (<30A) | |||
Output Voltage Precision | ±0.5% | |||
Efficiency | ≥94% | |||
General Specifications | Charging Standard | EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, | ||
DC Plugs | IEC 62196-3(CCS2) | |||
Display | 7”TFT Color touch screen | |||
Language | English/ Chinese or others on request | |||
RFID System | Mifare (Classic, DesFire EV1) or others on request | |||
Communication | LAN/Wi-Fi /GPRS (optional) | |||
Communication Protocols | OCPP1.6 | |||
Place of Installation | Outdoor | |||
Cooling Mode | forced air cooling | |||
Altitude | 2000m | |||
Waterproof Standard | IP54 | |||
Operating Temperature | -20~50℃ (Derating over 50℃) | |||
Storage Temperature | -40-70℃ | |||
Humidity | 5%~95% without condensation | |||
Sound Noise | <65 dB in all directions | |||
Length of Charging Cable | 5m (optional) | |||
Dimensions (W*D*H) | 750*550*1700mm |